Keshav Enterprises
Vacuum Circuit Breakers repairing servicing

Vacuum Circuit Breakers repairing servicing

MOQ : 1 Piece

Vacuum Circuit Breakers repairing servicing Specification

  • Rated Short Circuit Breaking Current
  • 25kA
  • Phase
  • Single Phase
  • Mechanical Life
  • >20,000 operations
  • Rated Short Circuit Making Current
  • 63kA peak
  • Breaking Capacity
  • 25kA - 40kA
  • Product Type
  • High Voltage
  • Installation Options
  • Panel/Fixed/Mobile
  • Function
  • Interrupts and isolates electrical circuit in vacuum environment
  • Poles Number
  • 1
  • Rated Voltage
  • 12kV, 24kV, 36kV
  • Rated Current
  • 800A - 3150A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Fuse characteristic and protective curves (as per IEC standards)
  • Temperature Protection
  • Integrated thermal relay protection
  • Weight
  • Approx. 40 kg
  • Color
  • WHITE
  • Tip Flexibility
  • 210 degrees
  • Compatibility
  • Hugemed VLM processors
  • Therapeutic Use
  • ICU, ER, pulmonology
  • Sizes Available
  • 2.2 mm-5.8 mm OD
  • Atraumatic Insertion
  • Pre-lubricated distal tip
  • Field of View
  • 120 degrees
  • Channel Support
  • Suction, BAL, biopsy
  • Working Channel Width
  • 600MM maximum
  • Angulation Up/Down
  • 210 range
  • Packing
  • Individually sterile packed
  • Contamination Risk
  • Eliminated by single-use
 

Vacuum Circuit Breakers repairing servicing Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • Piece
  • Delivery Time
  • Days
  • Main Domestic Market
  • Madhya Pradesh
 

About Vacuum Circuit Breakers repairing servicing

We are service provider of  VCB Servicing /Repairing/ Testing with highly skilled person to rectify any type of problem electrical as well as mechanical. 

We provides all type spares/interrupter ,CT ,PT Relays supply service and Testing also 

supply of remote panel, OLTC Panel APFC Panel



Comprehensive Servicing and Repairs

Our expert team provides both on-site and off-site repair and maintenance for Vacuum Circuit Breakers. From diagnostics and cleaning to replacement of copper-chrome alloy contacts and recalibration of operating mechanisms, we ensure your VCB operates at peak performance. Service includes checking interlocks, control supply, auxiliary contacts, and thermal protection to guarantee safety and compliance with IEC standards.


Safety and Reliability Features

Vacuum Circuit Breakers are equipped with advanced safety interlocks, integrated thermal relay protection, and highly insulating vacuum mediums. These features minimize electrical hazards and enable consistent operation even in harsh conditions. Rated up to IP54, the breakers are safeguarded against dust and water ingress, providing extended mechanical life beyond 20,000 operations.

FAQs of Vacuum Circuit Breakers repairing servicing:


Q: How is Vacuum Circuit Breaker servicing carried out on-site and off-site?

A: Servicing includes visual inspection, cleaning of internal components, testing of operating mechanisms (manual/electrical), interlock functionality checks, and replacement of worn copper-chrome alloy contacts. On-site servicing is ideal for minor repairs, while off-site allows for more extensive maintenance and calibration.

Q: What are the benefits of using copper-chrome alloy contacts in VCBs?

A: Copper-chrome alloy contacts offer excellent arc-quenching properties, superior conductivity, and enhanced durability, resulting in longer service life and reliable performance during high-current interruptions.

Q: When should routine maintenance of a Vacuum Circuit Breaker be performed?

A: Routine maintenance should be scheduled annually or as specified by the manufacturers guidelines, especially in environments with frequent switching operations. Preventive maintenance can help avoid unexpected failures and ensure consistent protection.

Q: Where can Vacuum Circuit Breakers be installed?

A: Vacuum Circuit Breakers are versatile and can be installed in panel, fixed, or mobile configurations. They are suitable for industrial plants, utility substations, and commercial buildings requiring reliable circuit protection.

Q: What is the process for checking the operating mechanism and interlocks during servicing?

A: Technicians inspect the spring-charged mechanism, verify manual and electrical operations, and test both mechanical and electrical safety interlocks. Issues are corrected, and functionality is confirmed per IEC standards, ensuring optimal safety and performance.

Q: How do auxiliary contacts and remote signaling improve VCB operation?

A: Auxiliary contacts allow integration with remote signaling systems, enabling real-time status monitoring and automated response for efficient system management and quicker fault resolution.

Q: What are the advantages of the IP54 protection class for these circuit breakers?

A: IP54-rated Vacuum Circuit Breakers are protected against limited dust ingress and water splashes, making them suitable for demanding operation environments and reducing the risk of electrical faults due to contamination.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Circuit Breakers Category

Circuit Breakers

Circuit Breakers

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Product Type : High Voltage

Poles Number : 1

Color : WHITE

Mechanical Life : 20,000 Operations

SF6 Gas Circuit Breakers servicing repairing Testing

SF6 Gas Circuit Breakers servicing repairing Testing

Minimum Order Quantity : 1 Piece

Phase : Double Phase

Product Type : High Voltage

Poles Number : 1

Color : WHITE

Mechanical Life : 10,000 operations (typical)

VCB Spare Parts

VCB Spare Parts

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Product Type : High Voltage

Poles Number : 1

Color : Red

ACB VCB Circuit Breaker Spare Parts

ACB VCB Circuit Breaker Spare Parts

Minimum Order Quantity : 1 Piece

Phase : Single Phase

Product Type : Conventional

Poles Number : 1



Back to top